Delay Flight

To delay a flight, and send out relevant messages, right-click on the flight leg and select Irregular Dly

 

  

 

IATA Standard

A screenshot of a computer

Description automatically generated

 

Always Recalculate

When checked TakeOff - Touchdown - Block On will be calculated automatically when you enter Block Off.

Delay Reason

According to IATA AHM 780, you can only have 2 delay reasons in a delay message. If you have more than two the delay reason will go in the EDL section of the message.

 

MVT

AV1530/17.AVKOT.LHR

ED170700

DLGC/AM

EDLAW/CA

SI lack of crew

Sub Delay

Does not apply to the IATA standard (defined by the parameter DelayCodeFormatIATA in Setup).

Delay Time

Does not apply to the IATA standard (Defined by the parameter EstimatedBlockOffTimeIATA in Setup).

Supplementary Information

Information to be included in the MVT message.

 

Click the NEXT button.

 

All messages to be generated according to the setup in the Automation Factory will be displayed on this screen.

A screenshot of a computer

Description automatically generated

 

Click the SAVE button to update the information and process the messages.

 

In the Gantt, you can see a note with the supplementary information, and the delay reasons.

A close-up of a yellow and black rectangle

Description automatically generated

A screen shot of a computer

Description automatically generated

 

The color of the flight will change color according to the Styles.

 

Non-IATA standard

 

If your airline doesn't follow IATA standards, we have the setup parameter "EstimatedBlockOffTimeIATA", change the parameter to FALSE.

A screenshot of a computer

Description automatically generated

 

Always Recalculate

When checked, TakeOff - Touchdown - Block On will be calculated automatically when you enter Block Off.

Delay Reason

According to IATA AHM 780, you can only have two delay reasons in a delay message. If you have more than two the delay reason will go in the EDL section of the message.

 

MVT

AV501/17.AVJON.CPH

ED170700

DLGC/AM/0005/0001

EDLCA/CA/0002/0007

Sub Delay

Does not apply to Delay messages.

Delay Time

Delay time is available.

Supplementary Information

Information to be included in the MVT message.

 

Click on ‘Next’ to send and save the message (see above).

 

Next Info

A screenshot of a computer

Description automatically generated

 

Next Info

Only block-off time can be entered.

Always Recalculate

Does not apply to this option.

Delay Reason

The split of the Delay reason into minutes doesn't make any sense in a Next info message.


MVT

AV501/17.AVJON.CPH

NI170700

DLGC/AM/0005/0001

EDLCA/CA/0002/0007

Sub Delay

Does not apply to Delay messages.

Delay Time

Delay time is available depending on SETUP.

Supplementary Information

Information to be included in the MVT message.

 

Click on ‘Next’ to send and save the message (see above).

 